醫(yī)用電子內(nèi)鏡常見故障的處理

來源:http://www.xbdqws.com.cn/ 發(fā)布時間:2023-06-17 瀏覽量:0

電子內(nèi)鏡按鈕失靈
Electronic endoscope button malfunction
電子內(nèi)鏡操縱部按鈕的表面膠皮很薄,在使用和清洗中容易破損產(chǎn)生針孔而導(dǎo)致按鈕進(jìn)水失靈。從按鈕的外觀上很難發(fā)現(xiàn)細(xì)小的針孔,因此,在內(nèi)鏡清洗之前要進(jìn)行測漏,以便及時發(fā)現(xiàn)漏水的部件進(jìn)行更換,防止故障進(jìn)一步擴(kuò)大。
The surface rubber of the electronic endoscope control button is very thin, which is prone to damage and pinholes during use and cleaning, leading to water ingress and malfunction of the button. It is difficult to detect small pinholes from the appearance of the button, therefore, leakage testing should be carried out before endoscopic cleaning to timely detect and replace leaking components and prevent further expansion of the fault.
電子內(nèi)鏡電氣接頭進(jìn)水
Water ingress into the electrical connector of the electronic endoscope
內(nèi)窺鏡設(shè)備維修人員認(rèn)為其電子內(nèi)鏡電氣接頭進(jìn)水的原因是清洗時忘蓋防水帽或防水帽故障,導(dǎo)致液體進(jìn)入電氣接頭腐蝕插座,造成電子內(nèi)鏡無法向圖像處理器傳輸信號。因此,需要定期對防水帽的密封性進(jìn)行檢查,及時維修或更換相關(guān)部件。
The maintenance personnel of the endoscope equipment believe that the reason for the water ingress into the electrical connector of the electronic endoscope is due to forgetting to cover the waterproof cap during cleaning or a malfunction of the waterproof cap, which causes liquid to enter the electrical connector and corrode the socket, causing the electronic endoscope to be unable to transmit signals to the image processor. Therefore, it is necessary to regularly inspect the sealing of the waterproof cap and repair or replace relevant components in a timely manner.
內(nèi)窺鏡設(shè)備維修
電子內(nèi)鏡圖像異常
Abnormal electronic endoscope image
電子內(nèi)鏡圖像經(jīng)常出現(xiàn)的問題有圖像偏暗、顏色異常、圖像時有時無等,將直接影響醫(yī)生的診斷。圖像偏暗時檢查冷光源的亮度、內(nèi)鏡導(dǎo)光束的情況、監(jiān)視器亮度及對比度的設(shè)置,并作相應(yīng)調(diào)整;顏色異常時,需重新做白平衡,并檢查監(jiān)視器亮度及對比度的設(shè)置;圖像時有時無往往是內(nèi)鏡連接圖像處理器的電纜接觸不良所致,此時,可通過處理電纜的電氣接口來排除故障。
The common problems that occur in electronic endoscope images include dim images, abnormal colors, and sometimes absent images, which directly affect the doctor's diagnosis. When the image is dim, check the brightness of the cold light source, the condition of the endoscopic guide beam, the setting of the monitor brightness and contrast, and make corresponding adjustments; When the color is abnormal, it is necessary to redo the white balance and check the brightness and contrast settings of the monitor; Sometimes the lack of images is often caused by poor contact of the cable connecting the endoscope to the image processor. In this case, the fault can be eliminated by processing the electrical interface of the cable.
內(nèi)鏡的日常維護(hù)及檢測工作十分重要,要做到小心使用,經(jīng)常測漏,發(fā)現(xiàn)問題及時處理,便可以大限度地減少內(nèi)鏡維修次數(shù),延長其使用壽命。更多相關(guān)事項(xiàng)就來我們網(wǎng)站http://www.xbdqws.com.cn咨詢!
The daily maintenance and testing of endoscopes are very important. It is important to use them carefully, frequently detect leaks, and promptly handle any problems found. This can greatly reduce the number of endoscopic repairs and extend their service life. For more related matters, come to our website http://www.xbdqws.com.cn consulting service
s
新聞資訊
聯(lián)系我們
  • 公司公司:匠仁醫(yī)療設(shè)備有限公司
  • 匠仁醫(yī)療山東濟(jì)南維修部
  • 聯(lián)系人:樊經(jīng)理
  • 電話:13153199508
  • 地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號德邁國際信息產(chǎn)業(yè)園6號樓101-2室
  • 匠仁醫(yī)療湖南長沙維修部
  • 聯(lián)系人:李經(jīng)理
  • 電話:13873135765
  • 地址:湖南省長沙市雨花區(qū)勞動?xùn)|路820號恒大綠洲14棟2409室
新聞資訊

樊經(jīng)理:13153199508     李經(jīng)理:13873135765

公司地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號德邁國際信息產(chǎn)業(yè)園6號樓101-2室  湖南省長沙市雨花區(qū)勞動?xùn)|路820號恒大綠洲14棟2409室

     

魯公網(wǎng)安備 37010402441281號

弥勒县| 蓝田县| 临湘市| 大姚县| 余庆县| 安化县| 喀喇沁旗| 武威市| 资中县| 绥化市| 遂川县| 大姚县| 武穴市| 开原市| 兰州市| 巧家县| 垦利县| 镇平县| 鄂托克前旗| 宁阳县| 浪卡子县| 晴隆县| 丹巴县| SHOW| 涪陵区| 清新县| 方山县| 枣强县| 方正县| 衡东县| 鄯善县| 建水县| 石河子市| 吉木萨尔县| 分宜县| 富川| 钟山县| 丹东市| 安乡县| 白山市| 东乌珠穆沁旗|